Show simple item record

dc.contributor.authorCueva-Príncipe, L.A.
dc.contributor.authorWahjuningrum, D.A.
dc.contributor.authorDjuanda, A.G.
dc.contributor.authorAgurto-Huerta, A.
dc.contributor.authorGuerrero, M.E.
dc.date.accessioned2025-10-31T18:42:51Z
dc.date.available2025-10-31T18:42:51Z
dc.date.issued2022
dc.identifier.urihttps://www.jidmr.com/journal/wp-content/uploads/2022/09/23-D22_1849_Dian_Agustin_Wahjuningrum_Indonesia.pdf
dc.identifier.urihttps://hdl.handle.net/20.500.12805/6001
dc.description.abstractDental implant systems using computer-aided surgical guide have advantages over the conventional procedures. A retrospective observational study was carried out to 56 dental implants placed according to surgical guide developed by CAD/CAM system. The guide included toothsupported, and mucosa-supported surgical guide and implant placement in all areas of the jaws. The virtual planning was superimposed on a tomography to evaluate the precision parameters including platform distance, apex distance, angular deviation, and depth of implants. Objectives to determine the accuracy of CAD/CAM system with a computer-aided surgery for dental implant placement based on the design and placement site. Regarding the precision parameters, the platform distance was at 1.38 mm (± 0.66), the apex distance at 1.63 mm (± 0.97), the angular deviation at 3.97º (± 3. 34º) for, and the depth of implants at 1.11 mm (± 0.97). 0.72). The precision parameters had no significant difference on the implant placement in the jaws, but there was a significant difference on the platform distance (p = 0.0096) according to the guide. It has been found that the tooth-supported surgical guide had the best precision. The precision of implant placement using computer-assisted surgical guides with the CAD/CAM system was maintained according to the antecedent precisión parameters. The guide design is a considerable factor for producing better precision as expected tooth-borne.en_US
dc.description.sponsorshipThe authors are grateful to the Ministry of Research, Technology and Higher Education, Indonesia, for the funding support thus this research oculd ebocnducted.
dc.formatapplication/pdf
dc.language.isoeng
dc.publisherUniversity of Dicle
dc.relation.ispartofurn:issn:1309-100X
dc.rightshttps://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectImplant Innovations in Orthodontics and Bone Healthen_US
dc.subjectPrecision Techniques in Dental Implant Surgeryen_US
dc.titlePrecision of the CAD/CAM Planmeca System Computer-Guided Surgery for the Placement of Dental Implantsen_US
dc.typehttps://purl.org/coar/resource_type/c_2df8fbb1
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.type.otherResearch article
dc.identifier.journalJournal of International Dental and Medical Research
dc.type.versionhttps://purl.org/coar/version/c_970fb48d4fbd8a85