Show simple item record

dc.contributor.authorWilliams, F.D.
dc.contributor.authorWatanabe-Kanno, G.A.
dc.contributor.authorWilliams, F.E.
dc.contributor.authorArriola-Guillén, L.E.
dc.date.accessioned2025-10-31T18:36:19Z
dc.date.available2025-10-31T18:36:19Z
dc.date.issued2021
dc.identifier.urihttps://hdl.handle.net/20.500.12805/5396
dc.description.abstractBackground: Digital models are considered the new standard in the clinical practice of orthodontics. However, they are difficult to use in the absence of a true scale for chairside use during clinical appointments. Therefore, an easy standardized method with true-scale paper print images would be of great utility. The aim of this study was to correlate and compare measurements obtained manually in true-scale paper printed images of digital models with those obtained digitally in the computer. Methods: Sixty desktop scanned digital models (30 upper and 30 lower) were analyzed. Ortho Insight 3D software was used for generating the printed images on paper and for measuring the digital models. Intercanine width, interpremolar width (first and second), intermolar width (first), and arch length measures were performed with both methods and were correlated and compared. Results: There was a high correlation between measurements performed with both methods. Values obtained from paper print images were lower and showed statistically significant differences (<0.4 mm; P < 0.001), which did not have any clinical implications. Conclusions: There is a high correlation between orthodontic measurements obtained manually in true-scale paper printed images of digital models and those obtained digitally in computer models, with no clinical differences between the two measurements. True-scale printed images of digital models can be used chairside in clinical appointments for the verification of measurements, or even as a guide for archwire individualization and shape bending without the need for long and complex processes or scale sizing adjustments.en_US
dc.formatapplication/pdf
dc.language.isoeng
dc.publisherElsevier
dc.relation.ispartofurn:issn:2212-4438
dc.rightshttps://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectMechanical Strength and Bonding in Dental Materialsen_US
dc.subjectDigital Innovations in Dental Procedures and Materialsen_US
dc.titleCorrelation of two different measuring methods for digital models: Manual on printed paper and digital in computer: A retrospective studyen_US
dc.typehttps://purl.org/coar/resource_type/c_2df8fbb1
dc.identifier.doihttps://doi.org/10.1016/j.ejwf.2021.03.001
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.type.otherResearch article
dc.identifier.journalJournal of the World Federation of Orthodontists
dc.type.versionhttps://purl.org/coar/version/c_970fb48d4fbd8a85


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

https://purl.org/coar/access_right/c_abf2
Except where otherwise noted, this item's license is described as https://purl.org/coar/access_right/c_abf2