| dc.contributor.author | Sarmiento, G. | |
| dc.contributor.author | Ayala, G. | |
| dc.contributor.author | Watanabe, R. | |
| dc.contributor.author | Salcedo-Moncada, D. | |
| dc.contributor.author | Alvítez-Temoche, D. | |
| dc.contributor.author | Mayta-Tovalino, F. | |
| dc.date.accessioned | 2025-10-31T18:35:55Z | |
| dc.date.available | 2025-10-31T18:35:55Z | |
| dc.date.issued | 2021 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12805/5346 | |
| dc.description.abstract | Aim: To compare microleakage in premolar class I restorations between nanohybrid and microhybrid composites in an in vitro study. Materials and Methods: Overall, 32 healthy premolar permanent teeth extracted for reasons unrelated to the study were used. Class I Black restorations were performed and divided into two groups. Group A: microhybrid resin, Group B: nanohybrid resin. Both groups were subjected to manual thermocycling (300 cycles at 5, 37, and 55°C), and they were then immersed in 2% methylene blue during 24h. Subsequently, the samples were washed, dried, sectioned, and observed under a stereoscopic microscope. Results: In the microhybrid resin composite (MRC) group, only two teeth (28.8%) did not show filtration (Grade 0), whereas eight of the specimens evaluated (80%) showed Grade 3 filtration (dye penetration to the pulpal floor). On the other hand, in the nanohybrid resin composite (NRC) group, the highest prevalence was found in Grade 1 (no dye penetration) in eight specimens (66.7%). There was no statistically significant association between the degree of filtration and the type of resin composite used (P = 0.089). Conclusions: Both materials showed microleakage, but the microhybrid resin presented a higher degree of filtration compared with the nanohybrid resin. No statistically significant association was found with the degree of microleakage between the resins. | en_US |
| dc.format | application/pdf | |
| dc.language.iso | eng | |
| dc.publisher | Wolters Kluwer Medknow Publications | |
| dc.relation.ispartof | urn:issn:0976-7428 | |
| dc.rights | https://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.subject | Mechanical Strength and Bonding in Dental Materials | en_US |
| dc.subject | Microleakage and Strength in Restorative Materials | en_US |
| dc.title | Microleakage in premolar class i restorations between nanohybrid and microhybrid composites: A comparative in vitro study | en_US |
| dc.type | https://purl.org/coar/resource_type/c_2df8fbb1 | |
| dc.identifier.doi | https://doi.org/10.4103/jioh.jioh_330_20 | |
| dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.14 | |
| dc.type.other | Research article | |
| dc.identifier.journal | Journal of International Oral Health | |
| dc.type.version | https://purl.org/coar/version/c_970fb48d4fbd8a85 | |