Show simple item record

dc.contributor.authorTinedo-López, P.L.
dc.contributor.authorMalpartida-Carrillo, V.
dc.contributor.authorOrtiz-Culca, F.
dc.contributor.authorGuerrero, M.E.
dc.contributor.authorAmaya-Pajares, S.P.
dc.contributor.authorözcan, M.
dc.date.accessioned2025-10-31T18:35:41Z
dc.date.available2025-10-31T18:35:41Z
dc.date.issued2020
dc.identifier.urihttps://hdl.handle.net/20.500.12805/5315
dc.description.abstractAim: To compare the vertical marginal discrepancy of retrievable cement/screw-retained design (RCSRD) and cement-retained (CR) implant-supported single metal copings cemented on implant abutments. Materials and methods: Single metal copings were fabricated for 20 4.5 × 10 mm titanium dental implants. Two groups of 10 implants each were randomly allocated. One group received RCSRD metal copings and the other group received CR metal copings. Both types of restorations were fabricated on solid abutments with 5.5 mm of diameter. The copings were cemented with resin cement. After the cementation procedure, cement excess was carefully removed in both groups. Inspections of coping-abutment vertical marginal discrepancy were measured using scanning electronic microscopy (SEM) under 800x magnification. The independent sample Student's t test was used to detect differences between groups (p<0.05). Results: The RCSRD implant-supported metal coping group (57.80 ± 2.34 μm) showed statistically better vertical marginal discrepancy than the CR implant-supported metal coping group (64.40 ± 2.23 μm) (p = 0.001). Conclusion: The RCSRD implant-supported metal copings offer less vertical marginal discrepancy than the CR copings group. This new technique would decrease the marginal discrepancy with less bacterial filtration and biomechanical problems. Clinical significance: Retrievable cement/screw-retained design is another alternative technique for dental implant rehabilitation that combines the advantages of CR and SR prostheses. The hybrid design offers less vertical marginal discrepancy for better control of bacterial filtration and biomechanical problems.en_US
dc.formatapplication/pdf
dc.language.isoeng
dc.publisherJaypee Brothers Medical Publishers
dc.relation.ispartofurn:issn:1526-3711
dc.rightshttps://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectImplant Innovations in Orthodontics and Bone Healthen_US
dc.subjectClinical Performance of Implant-Supported Restorationsen_US
dc.titleVertical Marginal Discrepancy of Retrievable Cement/Screw- Retained Design and Cement-Retained Implant-Supported Single Metal Copingsen_US
dc.typehttps://purl.org/coar/resource_type/c_2df8fbb1
dc.identifier.doihttps://doi.org/10.5005/JP-JOURNALS-10024-2905
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.type.otherResearch article
dc.identifier.journalJournal of Contemporary Dental Practice
dc.type.versionhttps://purl.org/coar/version/c_970fb48d4fbd8a85


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

https://purl.org/coar/access_right/c_abf2
Except where otherwise noted, this item's license is described as https://purl.org/coar/access_right/c_abf2