Show simple item record

dc.contributor.authorCustodio, N.
dc.contributor.authorMontesinos, R.
dc.contributor.authorAlva-Diaz, C.
dc.contributor.authorPacheco-Barrios, K.
dc.contributor.authorRodriguez-Calienes, A.
dc.contributor.authorHerrera-Pérez, E.
dc.contributor.authorBecerra-Becerra, Y.
dc.contributor.authorCastro-Suárez, S.
dc.contributor.authorPintado-Caipa, M.
dc.contributor.authorCruz del Castillo, R.
dc.contributor.authorCuenca, J.
dc.contributor.authorLira, D.
dc.date.accessioned2025-10-31T18:35:08Z
dc.date.available2025-10-31T18:35:08Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/20.500.12805/5240
dc.description.abstractIntroduction: To evaluate the diagnostic accuracy of three brief cognitive screening (BCS) tools, Peruvian version of Addenbrooke's Cognitive Examination (ACE-Pe), of INECO Frontal Screening (IFS-Pe) and of the Mini-Mental State Examination (MMSE-Pe), for the diagnosis of vascular cognitive impairment (VCI) and its non-dementia stages (VCI-ND) and vascular dementia (VD) in patients with cerebral stroke in Lima—Peru. Materials and methods: A cohort analysis to evaluate the diagnostic accuracy of three BCS for VCI. Results: Two hundred and four patients were evaluated: 61% Non-VCI, 30% VCI-ND and 9% VD. To discriminate patients with VCI from controls, the area under the curve (AUC) of ACE-Pe, IFS-Pe and MMs-Pe were 0.99 (95% confidence interval [CI] 0.98–0.99), 0.99 (95%CI 0.98–0.99) and 0.87 (95%CI 0.82–0.92), respectively. Of the three BCS, the IFS-Pe presented a larger AUC to discriminate VCI-ND from VD (AUC = 0.98 [95%CI 0.95–1]) compared to ACE-Pe (AUC = 0.84 [95%CI 0.74–0.95]) and MMSE-Pe (0.92 [95%CI 0.86–0.99]). The IFS-Pe presented a higher sensitivity (S), specificity (Sp), and positive (+LR) and negative likelihood ratios (−LR) (S = 96.72%, Sp = 89.47%, +LR = 9.1 and −LR = 0.03) than ACE-Pe (S = 96.72%, Sp = 63.16%, +LR = 2.62 and −LR = 0.05) and MMSE-Pe (S = 90.16%, Sp = 78.95%, +LR = 4.28 and −LR = 0.12). In the multiple regression analysis, the IFS-Pe was not affected by age, sex or years of schooling. Conclusion: The IFS-Pe has the best diagnostic accuracy for detecting VCI and discriminating between pre-dementia (VCI-ND) and dementia (VD) stages.en_US
dc.description.sponsorshipWe thank the neuropsychologist Patricia Cortijo and Carlos Gamboa for their contribution in evaluating the patients in the study. Authors declare that no funding was received for this study.
dc.formatapplication/pdf
dc.language.isoeng
dc.publisherJohn Wiley and Sons
dc.relation.ispartofurn:issn:1099-1166
dc.rightshttps://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectSDG 3en_US
dc.subjectCognitive Impairment and Neuroimaging in Alzheimer's Diseaseen_US
dc.subjectCognitive Assessment Tools and Traditional Medicine Correlationen_US
dc.titleDiagnostic accuracy of brief cognitive screening tools to diagnose vascular cognitive impairment in Peruen_US
dc.typehttps://purl.org/coar/resource_type/c_2df8fbb1
dc.identifier.doihttps://doi.org/10.1002/gps.5531
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.25
dc.type.otherResearch article
dc.identifier.journalInternational Journal of Geriatric Psychiatry
dc.type.versionhttps://purl.org/coar/version/c_970fb48d4fbd8a85


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

https://purl.org/coar/access_right/c_abf2
Except where otherwise noted, this item's license is described as https://purl.org/coar/access_right/c_abf2