Show simple item record

dc.contributor.authorFlores-Rodrigo, D.
dc.contributor.authorMeza-Mauricio, J.
dc.contributor.authorRetamal-Valdes, B.
dc.contributor.authorMayta-Tovalino, F.
dc.contributor.authorMendoza-Azpur, G.
dc.date.accessioned2025-10-31T18:34:58Z
dc.date.available2025-10-31T18:34:58Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/20.500.12805/5215
dc.description.abstractObjective: To determine the comfort level and reproducibility assessment of the probing pocket depth obtained with three different probes. Methods: A cross-sectional clinical study was conducted in accordance with the STROBE standards. Three different types of periodontal probes were selected: (1) University of North Carolina (UNC) probe, (2) World health organization (WHO) probe and (3) UNC12 COLORVUE probe. Three experienced and calibrated periodontists performed periodontal clinical assessments (probing depth) and pain assessment with the visual analogue scale (VAS). Results: The clinical evaluations were carried out in 13 volunteers who attended the dental clinic of the Universidad Científica del Sur (Lima, Peru). A total of 2106 periodontal clinical measurements were obtained (702 measurements per examiner). Each examiner evaluated 234 sites for each type of probe. When patient comfort values during the periodontal evaluation performed with the 3 types of probes were compared, the patients evaluated with the UNC12 COLORVUE probe perceived less pain with a mean value of 0.61, followed by the WHO probe and the UNC probe. When evaluating the clinical measurements, the UNC probe was observed to obtain the greatest mean depth on probing 1.4 + 0.5 mm, while with the UNC12 Colorvue probe, the values obtained were 1.1 + 0.3 mm, and with the WHO probe, 1.2 + 0.4 mm. Conclusions: Based on the periodontal probe used, experience of the examiner and the patient, we can conclude that the UNC12 Colorvue probe was the instrument that promoted the greatest comfort or the slightest response to pain, followed by the WHO probe. However, the use of the WHO probe resulted in obtaining the lowest reproducibility among depths on probing. The UNC probe produced the highest response to pain in the patients.en_US
dc.description.sponsorshipThe authors gratefully acknowledge the contribution of the evaluators Carmen Castro Ruiz, Dennis La Torre; and of all participants who completed the questionnaire.
dc.formatapplication/pdf
dc.language.isoeng
dc.publisherJohn Wiley and Sons
dc.relation.ispartofurn:issn:1601-5037
dc.rightshttps://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectInterconnections Between Oral Health and Systemic Diseasesen_US
dc.subjectPrecision Measurement Techniques in Periodontal Healthen_US
dc.titleLevel of patient comfort and measurement reproducibility of three different probes: A cross-sectional studyen_US
dc.typehttps://purl.org/coar/resource_type/c_2df8fbb1
dc.identifier.doihttps://doi.org/10.1111/idh.12545
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.type.otherResearch article
dc.identifier.journalInternational Journal of Dental Hygiene
dc.type.versionhttps://purl.org/coar/version/c_970fb48d4fbd8a85


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

https://purl.org/coar/access_right/c_abf2
Except where otherwise noted, this item's license is described as https://purl.org/coar/access_right/c_abf2