Show simple item record

dc.contributor.authorMejia, J.R.
dc.contributor.authorFernandez-Chinguel, J.E.
dc.contributor.authorDolores-Maldonado, G.
dc.contributor.authorBecerra-Chauca, N.
dc.contributor.authorGoicochea-Lugo, S.
dc.contributor.authorHerrera-Añazco, P.
dc.contributor.authorZafra-Tanaka, J.H.
dc.contributor.authorTaype-Rondan, A.
dc.date.accessioned2025-10-31T18:34:40Z
dc.date.available2025-10-31T18:34:40Z
dc.date.issued2021
dc.identifier.urihttps://hdl.handle.net/20.500.12805/5169
dc.description.abstractBackground: The accuracy of urine dipsticks to detect increased albuminuria is uncertain. We aimed to assess the diagnostic accuracy of urine dipsticks for detecting albuminuria.Methods: A systematic review of studies that assessed the diagnostic accuracy of urine dipstick testing for detecting albuminuria has been conducted (using as reference standard the albuminuria in a 24-hour sample or the albumin-to-creatinine ratio) in Scopus, PubMed, and Google Scholar. The risk of bias of the included studies has been assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Whenever possible, we performed meta-analyses for sensitivity and specificity. The certainty of the evidence has also been assessed using the Grading of Recommendations Assessment, Development, and Evaluation methodology.Results: A total of 14 studies have been included in this review, having assessed all albumin-to-creatinine ratio (ACR) as assessed standard. Each study used different dipstick types. The resulting pooled sensitivity and specificity for each cutoff point were as follows: for ACR >30 mg/g (13 studies): 0.82 (95% confidence interval: 0.76–0.87) and 0.88 (0.83–0.91); for ACR 30–300 mg/g (7 studies): 0.72 (0.68–0.77) and 0.82 (0.76–0.89); and for ACR >300 mg/g (7 studies): 0.84 (0.71–0.90) and 0.97 (0.95–0.99), respectively. An overall high risk of bias, an important heterogeneity in all pooled analysis, and a very low certainty of the evidence have been found.Conclusions: Pooled sensitivity and specificity of urine dipsticks have been calculated for different ACR cutoff points. However, the dipstick types differed across studies, and the certainty of the evidence was very low. Thus, further well-designed studies are needed to reach more confident estimates and to assess accuracy differences across dipstick types.Registration: PROSPERO (CRD42019124637)en_US
dc.description.sponsorshipThis research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors
dc.formatapplication/pdf
dc.language.isoeng
dc.publisherElsevier
dc.relation.ispartofurn:issn:2405-8440
dc.rightshttps://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectChronic Kidney Disease and Patient Care Dynamicsen_US
dc.subjectMicroalbuminuria as a Cardiovascular Risk Markeren_US
dc.titleDiagnostic accuracy of urine dipstick testing for albumin-to-creatinine ratio and albuminuria: A systematic review and meta-analysisen_US
dc.typehttps://purl.org/coar/resource_type/c_2df8fbb1
dc.identifier.doihttps://doi.org/10.1016/j.heliyon.2021.e08253
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#5.00.00
dc.type.otherResearch article
dc.identifier.journalHeliyon
dc.type.versionhttps://purl.org/coar/version/c_970fb48d4fbd8a85


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

https://purl.org/coar/access_right/c_abf2
Except where otherwise noted, this item's license is described as https://purl.org/coar/access_right/c_abf2