Show simple item record

dc.contributor.authorConde-López, S.
dc.contributor.authorFiori-Chicano, G.A.
dc.contributor.authorLlaguno-Rubio, J.
dc.contributor.authorArriola-Guillen, L.E.
dc.date.accessioned2025-10-31T18:33:20Z
dc.date.available2025-10-31T18:33:20Z
dc.date.issued2021
dc.identifier.urihttps://hdl.handle.net/20.500.12805/4917
dc.description.abstractThe objective of this work is to determine the utility of TCHC (Cone Beam Computed Tomography) for the measurement of bone density in orthodontic treatments by reviewing the literature. The application of forces in orthodontic treatment is responsible for a series of biological responses that occur in the periodontal ligament and alveolar bone; In the remodeling, the process of reabsorption and apposition occurs, consequently, the new bone formed presents a new bone density. BMD (Bone Mineral Density) is the amount of minerals (usually calcium and phosphorous) contained in a volume of bone, this includes porosity, marrow and bone matrix. The agglutination of these minerals is what makes the bone more or less dense. Due to this, it is important to quantify the BMD in patients prior to orthodontic treatment. Quantification of BMD is usually done with the Hounsfield Units (UH), the standard measure of Medical Computed Tomography (TCM), however, with the advancement of technology in dentistry, BMD measurements are started, with an equivalent to the UH, called gray value scale; this gray variation is the way to quantify the BMD with the TCHC. With this technological advance, a decrease in the amount of patient filing has been achieved, by reflection, shorter exposure time, lower cost and higher resolution. That is why you might consider a better option for evaluating BMD.en_US
dc.formatapplication/pdf
dc.language.isospa
dc.publisherEdiciones Avances
dc.relation.ispartofurn:issn:0213-1285
dc.rightshttps://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectEndodontics and Dental Regenerationen_US
dc.subjectCone Beam Computed Tomography in Dental Applicationsen_US
dc.titleUso de la tomografía computarizada de haz cónico para el estudio de la densidad ósea en el tratamiento ortodóncico. Una revisión de la literaturaes_PE
dc.title.alternativeUse of the cone beam computed tomography for the study of bone density in orthodontic treatment. A review of the literatureen_US
dc.typehttps://purl.org/coar/resource_type/c_2df8fbb1
dc.identifier.doihttps://doi.org/10.4321/s0213-12852021000400002
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.type.otherResearch article
dc.identifier.journalAvances en Odontoestomatologia
dc.type.versionhttps://purl.org/coar/version/c_970fb48d4fbd8a85


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

https://purl.org/coar/access_right/c_abf2
Except where otherwise noted, this item's license is described as https://purl.org/coar/access_right/c_abf2